Setup Konica Minolta C350 in CUPS
-
Select “Add Printer” from the “Administration” tab.
Name the printer and select continue.
Select AppSocket/HP JetDirect and click Continue (the selection here doesn't seem to matter).
Enter the printers IP address in the format: socket://192.168.0.7:9100. 192.168.0.7 is the IP and 9100 is the port.
Click continue.
Select Generic as the Make and click continue.
Select Generic PCL5c. Any of them will probably work, I used CUPS+Gutenprint which was the first on the list.
Click Add Printer.
Your done. Print a test page.